How threshold customisation affects the performance of a multiclass X-ray AI model for primary care triage: a retrospective study
BMJ Open, 2026
Abstract
Introduction: To describe the structured process of threshold optimisation for a commercially available multiclass chest X-ray (CXR) deep learning model, to evaluate its diagnostic performance across different operating thresholds, and to estimate its potential operational impact within an artificial intelligence (AI)-enabled triage workflow in a primary care setting.
Methods: Retrospective diagnostic performance evaluation with threshold-based analysis. Primary care radiography services in Singapore, using data derived from two primary care clinics and a tertiary hospital. A total of 816 adult frontal chest radiographs were included (multiethnic Asian, 464 males, 352 females; mean age 60.8 years). Images were selected to represent the spectrum of findings often encountered in primary care.
Results: At the default threshold of 0.15, the AI model achieved a sensitivity of 87.3% (95% CI 83.9% to 90.4%) and an NPV of 87.0% (95% CI 83.6% to 90.2%). Lowering the threshold to 0.10 increased sensitivity to 93.2% (95% CI 90.7% to 95.5%) and NPV to 91.3% (95% CI 88.2% to 94.3%), with specificity of 71.7% (95% CI 67.3% to 76.1%). These trade-offs were considered acceptable for a safety-focused co-triage workflow prioritising minimisation of false negatives.
Conclusion: Threshold optimisation is critical for adapting AI models to context-specific clinical workflows. Our study shows that adjusting the operating threshold enabled prioritisation of sensitivity and NPV, supporting safe AI-assisted triage in primary care. This is a deeply collaborative process that must involve radiology and clinical teams: selecting appropriate thresholds aligned with clinical objectives for safe and effective implementation. Future work will assess real-world operational impact and user acceptance following prospective deployment.