Comparing AI chest x-ray and CRP testing for TB screening in southern africa

Comparing AI chest x-ray and CRP testing for TB screening in southern africa

Product: Chest X-ray Company: Rayscape


Comparing AI Chest X-Ray and CRP Testing for TB Screening in Southern Africa

BMJ Open, 2025

Abstract

Introduction

Tuberculosis (TB) remains a significant public health challenge in many African communities, where underreporting and underdiagnosis are prevalent due to barriers in accessing care and inadequate diagnostic tools. This is particularly concerning in hard-to-reach areas with a high burden of TB/HIV co-infection, where missed or delayed diagnoses exacerbate disease transmission, increase mortality and lead to severe economic and health consequences. To address these challenges, it is crucial to evaluate innovative, cost-effective, community-based screening strategies that can improve early detection and linkage to care.

Methods and analysis

We conduct a prospective, community-based, diagnostic, pragmatic trial in communities of the Butha Buthe District in Lesotho and the Greater Edendale area of Msunduzi Municipality, KwaZulu-Natal in South Africa to compare two strategies for population-based TB screening: computer-aided detection (CAD) technology alone (CAD4TBv7 approach) versus CAD combined with point-of-care C reactive protein (CRP) testing (CAD4TBv7-CRP approach). Following a chest X-ray, CAD produces an abnormality score, which indicates the likelihood of TB.

Score thresholds informing the screening logic for both approaches were determined based on the WHO’s target product profile for a TB screening test. CAD scores above a threshold prespecified for the CAD4TBv7 approach indicate confirmatory testing for TB (Xpert MTB/RIF Ultra). For the CAD4TBv7-CRP approach, a CAD score within a predefined window requires the conduct of the second screening test, CRP, while a score above the respective upper threshold is followed by Xpert MTB/RIF Ultra. A CRP result above the selected cut-off also requires a confirmatory TB test. Participants with CAD scores below the (lower) threshold and those with CRP levels below the cut-off are considered screen-negative. The trial aims to compare the yield of detected TB cases and cost-effectiveness between two screening approaches by applying a paired screen-positive design. 20 000 adult participants will be enrolled and will receive a posterior anterior digital chest X-ray which is analysed by CAD software.

Read full study