Find the artificial intelligence based software for radiology that you are looking for. All products listed are available for the European market (CE marked).
Find the artificial intelligence based software for radiology that you are looking for. All products listed are available for the European market (CE marked).
32 of 309 products
32/309
products
|
Sort by:
All 4 chambers of the heart), Automated measurements include 2-dimensional (cardiac volumes, Both pw and cw measurements) and tissue doppler, M-mode (e.g. tricuspid annular plane systolic excursion), Spectral doppler (blood flow across all valves
Us2.ai supports cardiovascular disease diagnostics by providing machine learning based solutions that analyze and interpret echocardiograms, which are ultrasound images of the heart, creating patient reports, at scale, on mobile, on premises and cloud-based platforms.
Detection Aid, Exam Score, Region Analysis, Risk score
Transpara provides decision support during reading of 2D Full-Field Digital Mammography (FFDM) and 3D Digital Breast Tomosynthetis (DBT) to help improve clinical accuracy, reduce workload and optimize workflow. Transpara is intended to support healthcare professionals with detection and diagnosis of breast lesions or for assessment of breast density and breast cancer risk using radiological images of the breast. Version 2.1 includes temporal comparison up to 3 exams.
Detection of fractures, Dislocations and bone lesions, Effusions, Worklist prioritization
BoneView detects fractures, effusions, dislocations and bone lesions, and gives 3 different pre-diagnosis labels on the images: - POSITIVE when the confidence for the presence of a lesion is above 90% (plain bounding box around the region of interest) - DOUBT when the confidence for the presence of a lesion is between 50% and 90% (dotted bounding box around the region of interest) - NEGATIVE otherwise BoneView provides a summary table for quality check and overview of AI outputs at a glance, and can perform worklist prioritization according to the different pre-diagnoses. *In the United States, BoneView has been 510k FDA-cleared for pediatric use and adults (>2 years old for limbs).
Notification, Prioritisation, Pulmonary embolism triage
Aidoc's pulmonary embolism algorithm is a triage algorithm that alerts clinicians to the presence of one or more suspected pulmonary embolisms that are massive (high-risk), sub-massive (intermediate-risk) or low-risk acute pulmonary embolisms in all segments (central, lobar, segmental, sub-segmental). This algorithm is run on contrast enhanced CTs that are ordered for indications of a suspected pulmonary embolism.
PI-RADS 2.1 structured report, Prostate segmentation
QP-Prostate is a medical imaging software that supports radiologists in the detection of clinically significant prostate cancer. It provides automatic lesion detection and risk scoring (High and Moderate) for the presence of csPCa. It also provides quantitative information, including prostate volume and dimensions, Apparent Diffusion Coefficient (ADC) map, computed high b-value and perfusion metrics (K trans, K ep, V e). The information is compiled by the radiologist in a prostate structured report template based on PI-RADS guidelines.
Automated measurements of nodule diameter, Depth, Lung nodule detection, Volume
Riverain's CT Detect technology provides measurements for each detected region of interest including location, type, volume, maximum, minimum, average axial plane diameters, and nodule depth. All nodule types are detected (solid, part-solid, ground glass) at or above 5mm.
Notification, Prioritisation, Triage, Vertebral compression fracture
Aidoc's vertebral compression fracture algorithm is a triage algorithm that alerts clinicians to the suspected presence of vertebral compression fractures. This algorithm is run on chest and/or abdomen CTs with or without contrast.
Central pulmonary embolism triage, Notification, Prioritisation
Aidoc's pulmonary embolism algorithm is a triage algorithm that alerts clinicians to the presence of one or more suspected pulmonary embolisms that are massive (high-risk), sub-massive (intermediate-risk) or low-risk acute pulmonary embolisms in the central segment. This algorithm is run on contrast enhanced CTs that are ordered for indications of a suspected pulmonary embolism.
Maximum abdominal aortic diameter measurement
Aidoc's Abdominal Aortic Measurement analyzes all contrast enhanced CT exams that include the abdominal aorta, finding the maximal abdominal aortic diameter, orthogonal to blood flow, and provides a reformatted key slice image containing the maximal diameter, along with lines corresponding to that maximal diameter and its perpendicular shorter axis.
Midline shift measurement
Aidoc's midline shift algorithm is a quantification algorithm that automatically measures the farthest distance between the midline and the septum pellucidum of the brain. If the septum pellucidum is not aligned with the midline, it may indicate a midline shift which is a condition often associated with brain abnormalities.
Coronary Artery Calcification (CAC) scoring
Aidoc's coronary artery calcification algorithm is a quantification algorithm that opportunistically runs on non-gated, non-contrast CTs to provide radiologists with a measurement of the levels of calcified plaques within coronary arteries.
Malpositioned endotracheal tube triage, Notification, Prioritisation