United Imaging Intelligence
Company NameUnited Imaging Intelligence
Founded2017
Head officeShanghai, China
Websitehttps://www.uii-ai.com
ContactBusiness_UII@uii-ai.com

Products by United Imaging Intelligence

United Imaging Intelligence logo

Subspeciality: MSK

Modality: CT

Source: Vendor

Fracture detection list, Multiple fractures warning, Reconstructed images (MPR/MIP), Rib fracture detection, Rib fracture localization, Rib labeling, Rib vrt 3d reconstruction

The CT Rib Fracture Detection application is intended to detect suspicious rib fractures in chest CT images of adult patients. It detects rib fractures and provides rib labels of the detected fractures. The application also provides 3D visualization tools to render the detected fractures, facilitating radiologists to confirm or dismiss the software detected fractures.

United Imaging Intelligence logo

Subspeciality: Multiple

Modality: PET

Source: Vendor

AI-assisted screenshot, Automatic calculation of reference tissue uptakes, Follow-up comparison, Lesion localization, Lesion quantification, PET/CT registration and fusion

Detection of whole-body abnormal uptakes.

United Imaging Intelligence logo

Subspeciality: Chest

Modality: CT

Source: Vendor

PE triage result, Reconstructed images (mpr/vr/mip), Segmentation of pulmonary vessels

The CT PE Triage application is intended to provide a radiological computer-aided triage tool that assists in flagging studies with suspected positive findings of PE pathologies and offers viewing, manipulating and evaluating functionalities for CTPA images.

United Imaging Intelligence logo

Subspeciality: Cardiac

Modality: CT

Source: Vendor

Coronary lesion detection, Pericoronary fat measurement, Plaque analysis, Plaque detection, Reconstructed images (MPR/VR/MIP/Probe/CPR/SCPR), Segmentation and 3D reconstruction of heart and coronary arteries, Stenosis detection, Stenosis evaluation

The CT CCTA application is intended to assist in confirming and evaluating the presence or absence of coronary lesions for CCTA images.

United Imaging Intelligence logo

Subspeciality: Cardiac

Modality: CT

Source: Vendor

CT-FFR calculation, Line measurement, Segmentation of coronary vessels

The CT FFR application is intended to provide a coronary physiological simulation tool that generates CT-derived FFR measurements for CCTA images to assist in evaluating the structure and function of coronary arteries.

United Imaging Intelligence logo

Subspeciality: Cardiac

Modality: CT

Source: Vendor

Agatston score, Calcium mass, Calcium volume, Identification of calcifications, Segmentation of coronary arteries

The CT EKG-gated CACS application is intended to identify calcifications and calculate the calcium score of the coronary arteries based on EKG-gated noncontrated cardiac CT images.

United Imaging Intelligence logo

Subspeciality: Cardiac

Modality: CT

Source: Vendor

Agatston score, Calcium mass, Calcium volume, Identification of calcifications, Segmentation of coronary arteries

The CT Nongated CACS application is intended to identify calcifications and calculate the calcium score of the coronary arteries based on nongated noncontrated cardiac CT images.

United Imaging Intelligence logo

Subspeciality: Cardiac

Modality: CT

Source: Vendor

AIF and TAC curves, Myocardial ischemic parameters, Perfusion maps, Voxel- and aha segmental-level bull's eye maps

The CT CCTP application is intended to provide multiplanar reconstruction for myocardial CTP and CT-LIE images, TAC curves, bull's-eye maps, and perfusion parameters maps for myocardial CTP images.

United Imaging Intelligence logo

Subspeciality: Neuro

Modality: CT

Source: Vendor

CT, Intracranial hemorrhage, Stroke, Triage

CT Computer-Aided Triage Software is a radiological computer-assisted triage and notification software device indicated for analysis of non-contrast head CT images. The device is intended to assist trained radiologists in triage by flagging studies with suspected positive findings of intracranial hemorrhage (ICH), thereby optimizing physician workflow.

United Imaging Intelligence logo

Subspeciality: Neuro

Modality: CT

Source: Vendor

Detection of aneurysms, Radiology report, Reconstructed images (MPR/VR/MIP/Probe/CPR/SCPR), Segmentation of bones and arteries of the head and neck

The CT Cerebral CTA application is intended to assist in detecting and evaluating aneurysms for head and neck CTA images.