Find the artificial intelligence based software for radiology that you are looking for. All products listed are available for the European market (CE marked).
Find the artificial intelligence based software for radiology that you are looking for. All products listed are available for the European market (CE marked).
309 of 309 products
309/309
products
|
Sort by:
RV/LV ratio, Ventricle diameter quantification
RV/LV ratio can inform a physician on the severity of a Pulmonary Embolism by comparing the diameters of the right and left ventricles of the heart.
Fibrotic condition identification, Percentage of lung affected, Report generation, Volume quantification
Lung Texture Analysis ™ from Imbio automatically applies computer vision to transform a standard chest CT into a map of the lung textures to identify ILD's and other fibrotic conditions (normal, ground glass, reticular, honeycomb and hyperlucent). LTA's DICOM image series provides a texture overlay on the patient scan to highlight abnormalities and increase diagnostic confidence. LTA's physician summary report provides quantification of the textures by lung region.
Vertebral fracture detection on subject and vertebral level (absence/presence), Vertebral labeling of thoracic and lumbar spine
IB Lab FLAMINGO provides detection and labeling of vertebral fractures on a variety of CT imaging indications. The software provides prompt detection of vertebral fractures as secondary radiological findings. Furthermore, IB Lab FLAMINGO enables standardized detection of vertebral fractures as secondary radiological findings.
AP/PA full spine, Bracing support, Calibration ball support, Cobb angle, Coronal balance, Metalwork detection, Spinal alignment, Vertebral detection/labeling
IB Lab SQUIRREL is a radiological image processing software that aims to support physicians in the assessment of spinal morphology and scoliosis evaluation using frontal radiographs of the spine, particularly for the purpose of scoliosis assessment and disease progression. The algorithm is triggered automatically by a scoliosis study and returns relevant scoliosis parameters like the patient's Cobb angle and the Coronal Balance. The findings are summarized in a visual output report, attached to the original x-ray image and saved automatically in the PACS system.
12 radiological findings and measurements: genu varum, AMA angle, Anatomical angles according to paley, Femur length, Genu valgum, Hip knee angle, Joint line convergence angle, Lower extremity length discrepancy, Mechanical angles according to paley, Mechanical axis deviation (mad), Tibia length
IB Lab's diagnostic support tool LAMA uses deep learning technology for automated measuring of leg geometry to evaluate lower limb deformities, such as leg or lower extremity length discrepancy and knee alignment deformities.
10 radiological findings and measurements: lce-angle, Acetabular dysplasia, CCD-angle, Coxa valga, Coxa vara, Extrusion index/femoroacetabular coverage, Femoroacetabular impingement, Pelvic obliquity/leg length difference. for acetabular coverage measurements: tönnis angle, Sharp angle
HIPPO supports the objective and standardized measurement of the most important hip angles based on digital x-rays. These include, for example, the CCD and LCE angles as well as numerous other relevant angles for the diagnosis of hip disease including hip arthritis and hip dysplasia.
Bone age estimation, Growth Potential
PANDA sofware provides an automated method to estimate pediatric bone age, monitor child growth and development from digital X-rays of the hand.
Kellgren & Lawrence classification, OARSI classification, Osteoarthritis detection
Knee Osteoarthritis Labeling Assistant. Osteoarthritis is a paralyzing joint disease that can lead to joint replacement. Early detection as well as therapy can prevent unnecessary surgeries. Image Biopsy's lab module KOALA detects signs of knee osteoarthritis based on standard joint parameters and OARSI criteria of standing radiographs of the knee.
AIF/VOF graph, Mismatch ratio, Perfusion maps, Volume of core and perfusion lesion
icobrain cva allows the automated quantitative assessment of tissue perfusion by:
- reporting the volume of core and perfusion lesion by quantifying Tmax abnormality and CBF abnormality together with the mismatch volume and ratio,
- providing an AIF/VOF graph with information on the correctness of the selected arterial input function and the quality of the report,
- providing insights into the perfusion state of the tissue through perfusion maps.
icobrain cva is a cloud-based solution, returning a report and perfusion maps into the PACS and e-mail inbox.
Asymmetry index, Report generation, Volume quantification
icobrain ep helps physicians with the detection of hippocampal sclerosis in patients with intractable (uncontrollable) epilepsy.
Brain region quantification, Brain volume changes, Report generation
icobrain dm aims to assists healthcare professionals in achieving a diagnosis of dementia and Alzheimer's disease (AD). icobrain dm uncovers abnormality patterns by: - Reporting sensitive brain volumetrics to allow the early detection of AD and other diseases causing dementia (whole brain and ventricular volumes and ratio). - Quantifying and tracking cortical brain volumes and asymmetries to help with the differential diagnosis of the most common dementia types (frontal, parietal, temporal, occipital, and hippocampal cortex) - Comparing volumes and volume changes to an age-and sex-matched normative reference population. - Visualizing abnormality patterns in an intuitive volume signature.